This demo illustrates the connection between KIMEME and AMEsim to optimize the dimensions and characteristics of a check valve model in order to match a given pressure/flow characteristic.
Stroke: [1..10] mm
Spring Preload: [0..100] N
Stiffness: [0..100] N/mm
Seat diameter: [1..25] mm
Ball diameter: [1..30] mm
Ball diameter must be greater than the seat diameter
Minimize error (ISE) betweed actual flow rate valve and desired target (respectively green and black)
Nelder-Mead method
1500 evaluations, with parallel execution on 4 workstations using KIMEME Network. Execution time: 60 minutes.